Media 000479932: Vomer
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000479932: Vomer
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000479932
Media type
Mesh
Object element or part
Vomer
Object represented
Object taxonomy
Neusticemys neuquina
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Pablo González Ruiz
Date created
November 03, 2022
Date uploaded
November 03, 2022
FILE OBJECT DETAILS Field Definitions
File name
Vomer.stl
File format(s)
STL
File size
350 KB
Points
3583
Polygons
7158
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
11.106, 10.689, 50.391
Centroid coordinates
0.944, -22.146, -41.351
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(1 step)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric Lightspeed Pro 16 CT scanner, Departamento de Imágenes FUESMEN (Fundación Escuela de Medicina Nuclear (FUESMEN))
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
MHNSR:PV:1195
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Departamento de Imágenes FUESMEN (Fundación Escuela de Medicina Nuclear (FUESMEN))
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
139 kV
Power
--
Amperage
140µA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Stationary
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000478684: Skull [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Pablo González Ruiz
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000478684: Skull [CTImageSeries] [CT]
was processed
with 1 activity
to create
derived
Media 000479932: Vomer [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Pablo González Ruiz
Event date
--
Software
--
Description
--
Description attachment
None
Processing Activity 1:
Software
3D Slicer
Description
Media produced by this event on MorphoSource
Media 000479932: Vomer [Mesh] [CT] (this media)