Media 000490941: Element Unspecified
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

Media preview currently unavailable. Please check back later.

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000490941
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Hauffiopteryx typicus
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
January 10, 2023

FILE OBJECT DETAILS Field Definitions

File name
M1399_H_typicus.zip
File format(s)
ZIP archive
File size
3.38 GB
Image width
--
Image height
--
Color space
--
Color depth
--
Compression
--
X pixel spacing
0.158300
Y pixel spacing
0.158300
Z pixel spacing
0.250000
Pixel spacing units
Mm
Slice thickness
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Custom 225/450kV Walk In Micro focus, µ-VIS X-ray Imaging Centre (University of Southampton)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object brlsi:M1399 was imaged to create this media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
µ-VIS X-ray Imaging Centre (University of Southampton)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
90ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
1 frame per projections
Voltage
280 kV
Power
150.9 W
Amperage
539 microamps
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
0.1583
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

Media 000490941: Element Unspecified [CTImageSeries] [CT] (this media)