Media 000502088: Cranium
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000502088
Media type
Volumetric Image Series
Object element or part
Cranium
Object represented
Object taxonomy
Taeniolabis taoensis
Side
--
Orientation
--
Short description
--
Full description
Partial cranium missing dorsal and anterior portions of the snout and anterior parts of the zygomatic arches; poor surface preservation; found within in situ concretion.
Creator
Colbert, Matt
Date created
March 03, 2021
Date uploaded
March 09, 2023

FILE OBJECT DETAILS Field Definitions

File name
DMNH_EPV_134082.zip
File format(s)
ZIP archive, TIFF
File size
4.74 GB
Image width
1643
Image height
1121
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
73.700000
Y pixel spacing
73.700000
Z pixel spacing
73.700000
Pixel spacing units
Um
Slice thickness
--
Number of images in set
1,752

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dmnh:epv:134082 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Colbert, Matt
Event date
March 03, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000502088: Cranium [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Colbert, Matt
Event date
March 03, 2021
Software
--
Description
partial fossil mammal skull
Description attachment

Media produced by this event on MorphoSource

Media 000502088: Cranium [CTImageSeries] [CT] (this media)