Media 000512639: Element Unspecified
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000512639: Element Unspecified
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000512639
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Etheostoma perlongum
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Dylan Wainwright
Date created
September 22, 2019
Date uploaded
April 06, 2023
FILE OBJECT DETAILS Field Definitions
File name
Etheostoma.perlongum.YFTC37173.YPM_ICH_32699.recon.zip
File format(s)
ZIP archive, JPEG
File size
93.7 MB
Image width
590
Image height
442
Color space
YCbCr
Color depth
8
Compression
JPEG
X pixel spacing
14.059746
Y pixel spacing
14.059746
Z pixel spacing
14.059746
Pixel spacing units
Um
Slice thickness
--
Number of images in set
4,533
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Museum of Comparative Zoology Scanning Facility (Harvard University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Yale University
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
YPM:VZ:YPM ICH 032699.001
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Museum of Comparative Zoology Scanning Facility (Harvard University)
Creator
Dylan Wainwright
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 2 activities
to create
derived
Media 000512639: Element Unspecified [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Dylan Wainwright
Event date
September 22, 2019
Software
NRecon
Description
--
Description attachment
None
Processing Activity 1: Reconstruction
Software
NRecon
Description
Processing Activity 2: Crop
Software
FIJI
Description
Media produced by this event on MorphoSource
Media 000512639: Element Unspecified [CTImageSeries] [CT] (this media)