Media 000529809: Pelvic Girdle
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000529809
Media type
Mesh
Object element or part
Pelvic girdle
Object represented
Object taxonomy
Philoria sphagnicola
Side
--
Orientation
--
Short description
Pelvic girdle mesh
Full description
--
Creator
Roy M Farman
Date created
June 08, 2023
Date uploaded
June 08, 2023

FILE OBJECT DETAILS Field Definitions

File name
PhiloriasphagnicolaAMR96794pg.stl
File format(s)
STL
File size
20.1 MB
Points
211081
Polygons
422168
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
6.774, 9.100, 12.844
Centroid coordinates
2.856, -12.184, -12.748
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Inveon Multimodal Platform, University of New South Wales - Lowy Cancer Research Centre (University of New South Wales)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object am:herpetology:R.96794 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
University of New South Wales - Lowy Cancer Research Centre (University of New South Wales)
Creator
Roy M Farman
Event date
January 02, 2024
Software
Dragonfly
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived private media that exists on MorphoSource but is inaccessible with current user permissions.

Processing Details Field Definitions

Creator
Roy M Farman
Event date
January 02, 2024
Software
Dragonfly
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Private media inaccessible with current permissions

STEP 3: IMAGE PROCESSING

Derived private media was processed to create derived Media 000529809: Pelvic Girdle [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Roy M Farman
Event date
June 08, 2023
Software
Dragonfly
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000529809: Pelvic Girdle [Mesh] [CT] (this media)