Media 000530653: Cuboid
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000530653: Cuboid
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
No collections found.
TAGS
GENERAL DETAILS Field Definitions
Media ID
000530653
Media type
Mesh
Object element or part
cuboid
Object represented
Object taxonomy
Pelycodus mckennai
Object organization
Side
Left
Orientation
--
Short description
isolated fossil cuboid bone
Full description
--
Creator
Doug Boyer
Date created
June 14, 2023
Date uploaded
June 14, 2023
FILE OBJECT DETAILS Field Definitions
File name
UMMP_81824_Cantius_mckennai_L_cuboid_CTEES_CT.ply
File format(s)
PLY
File size
165 MB
Points
2179368
Polygons
4358732
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
6.472, 6.025, 7.714
Centroid coordinates
4.934, 4.576, 5.156
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(2 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Computed Tomography in Earth & Environmental Sciences (CTEES) (University of Michigan)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
The Regents of the University of Michigan
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
BCS 1552848
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UMMP:VP:81824
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Computed Tomography in Earth & Environmental Sciences (CTEES) (University of Michigan)
Creator
Adam Rountrey
Event date
June 09, 2023
Software
--
Description
this scan was done by technicians at UM CTEEs facility. For More information see the official web page for this scan https://doi.org/10.7302/zs0x-zw30
Description attachment
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 1 activity
to create
derived
Media 000530651: Cuboid [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Adam Rountrey
Event date
June 09, 2023
Software
--
Description
--
Description attachment
None
Processing Activity 1: Reconstruction
Software
Description
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000530651: Cuboid [CTImageSeries] [CT]
was processed
with 1 activity
to create
derived
Media 000530653: Cuboid [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Doug Boyer
Event date
June 14, 2023
Software
Avizo
Description
--
Description attachment
None
Processing Activity 1: Reconstructed Tomography to Mesh
Software
Avizo
Description
Media produced by this event on MorphoSource
Media 000530653: Cuboid [Mesh] [CT] (this media)