Media 000562877: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

GENERAL DETAILS Field Definitions

Media ID
000562877
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Strix aluco
Side
--
Orientation
--
Short description
Specimen of Strix aluco with 360° left head turn.
Full description
Specimen of Strix aluco with 360° head turn to the left. Part of study of the three-dimensional configuration of owl's neck in extreme head turn. Presented in publications as Strix aluco ad.
Creator
Aleksandra Panyutina
Date created
October 19, 2021
Date uploaded
September 20, 2023

FILE OBJECT DETAILS Field Definitions

File name
Strix-aluco-ad-twist.zip
File format(s)
ZIP archive, DICOM
File size
5.17 GB
Image width
1238
Image height
1350
Color space
--
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.064980
Y pixel spacing
0.064980
Z pixel spacing
0.064980
Pixel spacing units
Mm
Slice thickness
0.0649803
Number of images in set
2,023

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric Phoenix V|tome|x M300, All Russian Scientific Research Institute of Radio Electronics FGBU VNIIR (All Russian Scientific Research Institute of Radio Electronics FGBU VNIIR)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object PC-AP:B-149 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
All Russian Scientific Research Institute of Radio Electronics FGBU VNIIR (All Russian Scientific Research Institute of Radio Electronics FGBU VNIIR)
Creator
--
Event date
October 12, 2021
Software
Phoenix datos|x
Description
Specimen of Strix aluco with 360° head turn to the left. Part of study of the three-dimensional configuration of owl's neck in extreme head turn.
Description attachment
Reference attachment
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
1500
Voltage
150
Power
--
Amperage
100
Surrounding material
PET bottle and polyethylene pieces
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2024
Detector pixels size X
--
Detector pixels Y
2024
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000562877: Element Unspecified [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
October 19, 2021
Software
Phoenix datos|x
Description
Obtained raw projection data from the scanner (back projections) were converted into volume with the software shipped with the Phoenix V|tome|x scanner (Phoenix datos|x). Then, series of cross-section images (slices) were exported from the volume and saved in DICOM format. At this step, the software always reverses the right-left polarity (Z axis direction) of the specimen relative to its cranial-caudal polarity. Thus, in DICOM, the head turn to the right side is displayed as if it was the turn to the left. The true direction of turn is pointed out in the respective description.
Description attachment
None

Processing Activity 1: Crop

Software
Phoenix datos|x
Description

Media produced by this event on MorphoSource

Media 000562877: Element Unspecified [CTImageSeries] [CT] (this media)