Media 000535661: Cranium
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000535661: Cranium
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000535661
Media type
Mesh
Object element or part
Cranium
Object represented
Object taxonomy
Isoodon auratus
Object organization
Side
Midline
Orientation
--
Short description
Midline cranium of Isoodon auratus
Full description
--
Creator
Fusco, Diana
Date created
May 16, 2023
Date uploaded
June 30, 2023
FILE OBJECT DETAILS Field Definitions
File name
M4734_Isoodon_auratus_cranium_M_ct.ply
File format(s)
PLY
File size
29.4 MB
Points
809906
Polygons
1620152
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
24.576, 49.630, 23.313
Centroid coordinates
53.643, 43.699, 45.916
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
1
(1 step)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Medical Device Research Institute (Flinders University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
The Museum Board of South Australia
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
CABAH
Publisher
Ozboneviz
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
SAMA:Mammalogy:M4734
was imaged to create
raw
Media 000535651: Skeleton [CTImageSeries] [CT].
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Medical Device Research Institute (Flinders University)
Creator
Rapagna, Sophie
Event date
January 18, 2023
Software
--
Description
--
Description attachment
None
Reference attachment
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
Media produced by this event on MorphoSource
STEP 2: IMAGE PROCESSING
Raw
Media 000535651: Skeleton [CTImageSeries] [CT]
was processed
with 1 activity
to create
derived
Media 000535661: Cranium [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Fusco, Diana
Event date
May 16, 2023
Software
Materialise Mimics
Description
Segmentation
Description attachment
None
Processing Activity 1: Smoothing/Noise Reduction
Software
Geomagic
Description
Removed spikes
Media produced by this event on MorphoSource
Media 000535661: Cranium [Mesh] [CT] (this media)