Media 000541574: Entire Specimen
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000541574: Entire Specimen
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000541574
Media type
Volumetric Image Series
Object element or part
entire specimen
Object represented
Object taxonomy
Indoreonectes keralensis
Object organization
Side
NotApplicable
Orientation
--
Short description
microCT volume and derivatives
Full description
Record created by batch submission.
Creator
Zach Randall
Date created
--
Date uploaded
July 13, 2023
FILE OBJECT DETAILS Field Definitions
File name
USNM_Fish_268633.zip
File format(s)
ZIP archive, TIFF
File size
720 MB
Image width
404
Image height
496
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.020071
Y pixel spacing
0.020071
Z pixel spacing
0.020071
Pixel spacing units
Mm
Slice thickness
0.02007089
Number of images in set
2,022
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Blackburn, D.C., et al. 2024. Increasing the impact of vertebrate scientific collections through 3D-imaging: the openVertebrate (oVert) Thematic Collections Network. BioScience 74: 169–186. https://doi.org/10.1093/biosci/biad120
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
USNM:FISH:USNM 268633
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zach Randall
Event date
--
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
None
Exposure time
250.097
Flux normalization
no
Pixel spacing calibration
--
Shading correction
no
Frame averaging
3
Projections
960
Voltage
80
Power
0.016
Amperage
200
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
2024
Detector pixels size X
0.2
Detector pixels Y
2024
Detector pixels size Y
0.2
Detector configuration
Area (single or tiled detector)
Source object distance
80.01521576
Source detector distance
797.32613998
Target material
tungston
Rotation number
--
Phase contrast
no
Optical magnification
no
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000541574: Entire Specimen [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Zach Randall
Event date
--
Software
DatosX|R
Description
--
Description attachment
None