Media 000545335: Body+Tail
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000545335: Body+Tail
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000545335
Media type
Volumetric Image Series
Object element or part
Body+Tail
Object represented
Object taxonomy
Carcharodon carcharias
Object organization
Side
--
Orientation
--
Short description
--
Full description
Scan of the caudal fin of a 1307 mm TL great white shark.
Creator
--
Date created
--
Date uploaded
July 27, 2023
FILE OBJECT DETAILS Field Definitions
File name
LACM 43805-1 White Shark CT Scan.zip
File format(s)
ZIP archive, DICOM
File size
982 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.818359
Y pixel spacing
0.818359
Z pixel spacing
0.400000
Pixel spacing units
Mm
Slice thickness
1
Number of images in set
1,237
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens SOMATOM SensationVR 64-slice, Children's Hospital of Chicago Department of Medical Imaging ( Ann & Robert H. Lurie Children's Hospital of Chicago)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Natural History Museum of Los Angeles County
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
LACM:Fish:43805-1
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Children's Hospital of Chicago Department of Medical Imaging ( Ann & Robert H. Lurie Children's Hospital of Chicago)
Creator
--
Event date
--
Software
InSpace
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
120 kVp
Power
--
Amperage
200 mAs
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
0.33 sec
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000545335: Body+Tail [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000545335: Body+Tail [CTImageSeries] [CT] (this media)