Media 000633157: Whole Body
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000633157: Whole Body
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000633157
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Craugastor montanus
Object organization
Side
--
Orientation
--
Short description
--
Full description
microCT volume, zipped 16-bit tiff stack. Data inverted following reconstruction.
Record created by batch submission.
Creator
Chandrashekar, Chirag
Date created
February 05, 2024
Date uploaded
May 30, 2024
FILE OBJECT DETAILS Field Definitions
File name
UTEP_HERP_8335_Craugastor_montanus.zip
File format(s)
ZIP archive, TIFF
File size
646 MB
Image width
416
Image height
1201
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.054351
Y pixel spacing
0.054351
Z pixel spacing
0.054351
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
993
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
0
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 520 Versa X-ray Microscope (XRM), Materials Instrumentation and Multimodal Imaging Core Facility (MIMIC) (University of Colorado, Boulder)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert TCN partner NSF DBI-1701714; oMeso PEN NSF DBI-2001474
Publisher
--
Cite as
UTEP (catalog number)
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UTEP:Herp:UTEP:Herp:8335
was imaged to create
this media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Materials Instrumentation and Multimodal Imaging Core Facility (MIMIC) (University of Colorado, Boulder)
Creator
--
Event date
February 05, 2024
Software
Scout-and-Scan Control System
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.400000005960464
Flux normalization
--
Pixel spacing calibration
Geometry
Shading correction
--
Frame averaging
--
Projections
1601
Voltage
150
Power
0.01
Amperage
66.6666666666666
Surrounding material
--
X-ray tube type
--
Target type
Transmission
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
tungsten
Rotation number
--
Phase contrast
--
Optical magnification
true
Acquisition type
Sequenced
Media produced by this event on MorphoSource
Media 000633157: Whole Body [CTImageSeries] [CT] (this media)