Media 000590262: Left Humerus
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000590262: Left Humerus
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000590262
Media type
Volumetric Image Series
Object element or part
Left humerus
Object represented
Object taxonomy
Aves indet.
Object organization
Side
--
Orientation
--
Short description
--
Full description
Left humerus; block (large) with radius, ulna, quadrate, skull fragments, femur fragment, ungual phalanx; block (small) with metatarsus, vertebrae, several pedal phalanges
Creator
Marilyn Fox
Date created
January 06, 2023
Date uploaded
December 08, 2023
FILE OBJECT DETAILS Field Definitions
File name
Block_1_Tiff_Stack.zip
File format(s)
ZIP archive, TIFF
File size
613 MB
Image width
508
Image height
516
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
82.926400
Y pixel spacing
82.926400
Z pixel spacing
82.926400
Pixel spacing units
Um
Slice thickness
--
Number of images in set
1,698
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon XT H 225 ST 2X, Yale Chemical and Biophysical Instrumentation Center (CBIC) (Yale University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ypm:vp:059473
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Yale Chemical and Biophysical Instrumentation Center (CBIC) (Yale University)
Creator
Marilyn Fox
Event date
January 06, 2023
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
128
Projections
3142
Voltage
104
Power
--
Amperage
101
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000590262: Left Humerus [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Marilyn Fox
Event date
January 06, 2023
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000590262: Left Humerus [CTImageSeries] [CT] (this media)