Media 000596059: Quadrate
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

GENERAL DETAILS Field Definitions

Media ID
000596059
Media type
Mesh
Object element or part
Quadrate
Object represented
Object taxonomy
Hutchemys rememdium
Side
--
Orientation
--
Short description
Left Quadrate
Full description
Left Quadrate of NDGS 10029
Creator
--
Date created
January 10, 2024
Date uploaded
January 10, 2024

FILE OBJECT DETAILS Field Definitions

File name
Hutchemys_rememdium_NDGS_10029_L_Quadrate.ply
File format(s)
PLY
File size
31.4 MB
Points
745020
Polygons
1500444
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
14.956, 30.705, 19.336
Centroid coordinates
44.302, 41.300, 10.930
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging X3000, North Star Imaging Facility (North Star Imaging Facility)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
North Dakota Geological Survey
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object NDGS:10029 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
North Star Imaging Facility (North Star Imaging Facility)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
150 kV
Power
--
Amperage
150 µA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000595972: Cranium [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000595972: Cranium [CTImageSeries] [CT] was processed to create derived Media 000596059: Quadrate [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000596059: Quadrate [Mesh] [CT] (this media)