Media 000600880: 4th Cervical Vertebra
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000600880: 4th Cervical Vertebra
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000600880
Media type
Volumetric Image Series
Object element or part
4th cervical vertebra
Object represented
Object taxonomy
Masiakasaurus knopfleri
Object organization
Side
Midline
Orientation
--
Short description
4th cervical vertebra
Full description
--
Creator
McDiarmid, Fisher
Date created
January 31, 2024
Date uploaded
January 31, 2024
FILE OBJECT DETAILS Field Definitions
File name
UA_9106.zip
File format(s)
ZIP archive, DICOM
File size
1.17 GB
Image width
888
Image height
893
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.049300
Y pixel spacing
0.049300
Z pixel spacing
0.049300
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,149
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric eXplore CT 120 in vivo, Ohio University MicroCT Facility (Ohio University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
O'Connor, Patrick
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF EAR_9418817; Ohio University Heritage College of Osteopathic Medicine; NSF EAR_1123642; NSF DBI_2242718; NSF EAR_1525915
Publisher
O'Connor, Patrick; Mahajanga Basin Project
Cite as
Patrick M. O'Connor and colleagues provided access to these data. Data collection and processing funded by the US NSF EAR_9418816, NSF EAR_1123642, NSF EAR_1525915, NSF DBI_2242717 and Ohio University Heritage College of Osteopathic Medicine. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ua:9106
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Ohio University MicroCT Facility (Ohio University)
Creator
Ridgley, Ryan; Witmer, Larry
Event date
December 15, 2023
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
20ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
4
Projections
--
Voltage
120kV
Power
--
Amperage
32mA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000600880: 4th Cervical Vertebra [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
McDiarmid, Fisher
Event date
January 18, 2024
Software
Avizo
Description
Cropping and output as dicoms to replace field number(s) with museum accession number.
Description attachment
None
Media produced by this event on MorphoSource
Media 000600880: 4th Cervical Vertebra [CTImageSeries] [CT] (this media)