Media 000607267: Skull
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
· Public
Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000607267
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Otospermophilus variegatus
Side
--
Orientation
--
Short description
HRXCT scan of skull
Full description
University of Texas High-Resolution X-ray CT Facility Archive 0368 Swidersk: variegat: Warp corrected scans of the skull of a male Spermophilus variegates (UM 77495; Arizona, Cochise Co., 4 miles SW of Portal, collected by V. H. Calahane #315) . Scanned for Don Swiderski of the University of Michigan, Museum of Zoology. Scanned by Matthew Colbert on 7/28/00. Original scans on Archive 0253. Warp corrections applied by Holly Nance, April 2001. Original scan parameters. II, 120 kV, 0.2 mA, no filter, air wedge, 160% offset, slice thickness 3 lines (= 0.1483 mm), S.O.D. 85 mm, 1200 views, 2 samples per view, interslice spacing 3 lines (=0.1483 mm), field of reconstruction 40 mm (maximum field of view 43.14 mm), reconstruction offset 530, reconstruction scale 33. Scanned in three-slice mode. warpcorr (16bit): The above images modified with IDL software “Unwarp v.1.0” written by Dr. Richard Ketcham to correct for radial distortion of images introduced by ACTIS scanning software. Corrected images are now 522 pixels by 522 pixels, resulting in a revised field of reconstruction of 40.781 mm.
Creator
Matthew Colbert
Date created
July 28, 2000
Date uploaded
February 26, 2024

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
91.2 MB
Image width
520
Image height
444
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.078100
Y pixel spacing
0.078100
Z pixel spacing
0.148300
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
424

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
University of Michigan Museum of Zoology (Copyright and License)
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242, IIS-9874781
Publisher
oUTCT PEN
Cite as
Funding for scanning was provided by NSF grant IIS-9874781 to Tim Rowe. Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ummz:mammals:77495 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
July 28, 2000
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000607267: Skull [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource