Media 000607789: Rt Manus
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000607789
Media type
Volumetric Image Series
Object element or part
rt_manus
Object represented
Object taxonomy
Citipati osmolskae
Side
--
Orientation
--
Short description
--
Full description
Record created by batch submission.
Creator
AMNH
Date created
--
Date uploaded
February 29, 2024

FILE OBJECT DETAILS Field Definitions

File name
Citipati_osmolskae_IGM_100_978_rt_ manus_8bit.zip
File format(s)
ZIP archive, TIFF
File size
1.89 GB
Image width
1083
Image height
2946
Color space
BlackIsZero
Color depth
8
Compression
Uncompressed
X pixel spacing
0.096736
Y pixel spacing
0.096736
Z pixel spacing
0.096736
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,657

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x, AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
American Museum of Natural History
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object igm:MAE:100/978 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.5
Flux normalization
--
Pixel spacing calibration
--
Shading correction
true
Frame averaging
4
Projections
3000
Voltage
200
Power
--
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000607789: Rt Manus [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000607789: Rt Manus [CTImageSeries] [CT] (this media)