Media 000622401: Radius Distal Metaphysis
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000622401: Radius Distal Metaphysis
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
Media preview currently unavailable. Please check back later.
In Collections
Project
ยท Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000622401
Media type
Volumetric Image Series
Object element or part
radius distal metaphysis
Object represented
Object taxonomy
Homo sapiens
Object organization
Side
Left
Orientation
--
Short description
--
Full description
Information on the DHOC can be found in Belcastro et al. 2017, https://doi.org/10.1002/oa.2605; Belcastro et al. 2022, https://doi.org/10.3390/forensicsci2020025. The media were virtually acquired for the H2020 MSCA BABY PACE (2020-2023) granted by Antony Colombo and included in: Colombo et al., 2022. Variations of the trabecular bone microarchitecture through the period of locomotor behaviour development of a late 19th century post-industrial Italian population. JBMR Plus, 6, Issue S1, e10676, pp. 105-105 (10.1002/jbm4.10676); Colombo et al., 2022. Trabecular bone microarchitecture of the radial and femoral distal metaphyses during the period of locomotor behavior development. AMERICAN JOURNAL OF BIOLOGICAL ANTHROPOLOGY, 177, issue S73, pp. 35-35 (10.1002/ajpa.24514); Colombo et al., 2022. How does rickets impair locomotor development in children? Analysis of the trabecular bone microarchitecture of the distal radial metaphysis. 49th Annual North American Meeting of the of the Paleopathology Association, Denver, Etats-Unis, 21-23 mars.
Record created by batch submission.
Creator
Antony Colombo
Date created
--
Date uploaded
April 19, 2024
FILE OBJECT DETAILS Field Definitions
File name
BO_39_M_nad_radius_dist.zip
File format(s)
ZIP archive, TIFF
File size
1.23 GB
Image width
1360
Image height
1360
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.008740
Y pixel spacing
0.008740
Z pixel spacing
0.008740
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,425
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker Skyscan 1072, IOR Radiology Unit (Istituto Ortopedico Rizzoli)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
This data is part of the Virtual DHOC of the Certosa Cemetery of Bologna (Italy), housed at the Department of Biological, Geological and Environmental Sciences of the University of Bologna. Information on the DHOC can be found in Belcastro et al. 2017, https://doi.org/10.1002/oa.2605; Belcastro et al. 2022, https://doi.org/10.3390/forensicsci2020025. Downloaded from www.morphosource.org.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UNIBO:LabAntro:BO_39_M_nad
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
IOR Radiology Unit (Istituto Ortopedico Rizzoli)
Creator
--
Event date
--
Software
--
Description
[System]
Scanner=SkyScan1176
Instrument S/N=11C08036
Hardware version=A
Software=Version 1. 1 (build 11)
Home directory=C:\SkyScan1176
Source Type=PANalytical's Microfocus Tube
Camera=Princeton Instruments
Camera Pixel Size (um)= 12.42
CameraXYRatio=0.9980
Bed shift in X per 1000 lines=0.000000
Bed shift in Y per 1000 lines=-4.798464
[Acquisition]
Image Pixel Size (um)= 8.74
Filename Index Length=4
Number of Files= 721
Source Voltage (kV)= 45
Source Current (uA)= 556
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000622401: Radius Distal Metaphysis [CTImageSeries ] [CT] (this media).
Processing Details Field Definitions
Creator
Antony Colombo
Event date
--
Software
Avizo
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000622401: Radius Distal Metaphysis [CTImageSeries ] [CT] (this media)