Media 000636263: Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000636263
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Homotherium serum
Side
--
Orientation
--
Short description
HRXCT scan -- skull
Full description
University of Texas High-Resolution X-ray CT Facility Archive 1478 VanValkenburgh: Homotherium: Scans the skull of Homotherium serum (TMM 933-3444; Pleistocene & Holocene - Rancholabrea; Friesenhahn Cave, Texas; Bexar Co.; Zone 2, top) for Blaire Van Valkenburgh of the University of California Los Angeles Department of Organismic Biology, Ecology and Evolution. Specimen scanned by Matthew Colbert 31 August 2006. 16bit: 1024x1024 16-bit TIFF images. P250D, 419 kV, 1.8 mA, 1 brass filter, empty container wedge, 160% offset, 32 ms integration time, slice thickness = 0.75 mm, S.O.D. 595 mm, 1000 views, 1 ray averaged per view, 1 sample per view, inter-slice spacing = 0.65 mm, field of reconstruction 195 mm (maximum field of view 195.073 mm), reconstruction offset 6400, reconstruction scale 9000. Total slices = 495.
Creator
Matthew Colbert
Date created
August 31, 2006
Date uploaded
June 10, 2024

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
598 MB
Image width
964
Image height
904
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.190000
Y pixel spacing
0.190000
Z pixel spacing
0.650000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
495

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Memorial Museum
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
Data acquired for Blaire Van Valkenburgh. Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object txvp:vpl:933-3444 was imaged to create this media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
August 31, 2006
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

Media 000636263: Skull [CTImageSeries] [CT] (this media)