Media 000643627: Head
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000643627
Media type
Volumetric Image Series
Object element or part
Head
Object represented
Object taxonomy
Monomeropus malispinosus
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
July 09, 2024

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
743 MB
Image width
1128
Image height
1581
Color space
BlackIsZero
Color depth
8
Compression
Uncompressed
X pixel spacing
0.027000
Y pixel spacing
0.027000
Z pixel spacing
0.027000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,889

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1273, Museum of Comparative Zoology Scanning Facility (Harvard University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCZ:Ich:28649 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Museum of Comparative Zoology Scanning Facility (Harvard University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000643627: Head [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000643627: Head [CTImageSeries] [CT] (this media)