Media 000647933: Shet Sample2 08
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000647933: Shet Sample2 08
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000647933
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Limacina retroversa
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Bryce Koester
Date created
May 01, 2023
Date uploaded
July 18, 2024
FILE OBJECT DETAILS Field Definitions
File name
Shet_sample2_08_seg.zip
File format(s)
ZIP archive, DICOM
File size
361 MB
Image width
667
Image height
479
Color space
--
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.000700
Y pixel spacing
0.000700
Z pixel spacing
0.700000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
592
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 620 Versa x-ray microscope (xrm), The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ANSP:IP:23B_X8
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
February 28, 2023
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
2 seconds
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
80 kV
Power
10 W
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 1 activity
to create
derived
Media 000647933: Shet Sample2 08 (this media).
Processing Details Field Definitions
Creator
Bryce Koester
Event date
May 01, 2023
Software
Dragonfly
Description
--
Description attachment
None
Processing Activity 1: Background Removal and/or Masking
Software
Dragonfly
Description
Media produced by this event on MorphoSource
Media 000647933: Shet Sample2 08 (this media)