Media 000653912: Skull Braincase Image Stack
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000653912
Media type
Volumetric Image Series
Object element or part
Skull Braincase Image Stack
Object represented
Object taxonomy
Plesiosuchus manselii
Side
--
Orientation
--
Short description
Skull Braincase
Full description
--
Creator
--
Date created
--
Date uploaded
August 04, 2024

FILE OBJECT DETAILS Field Definitions

File name
Plesiosuchus_manselii_NHMUK_PV_R_1089.zip
File format(s)
ZIP archive, BMP
File size
403 MB
Image width
1907
Image height
1625
Color space
--
Color depth
24
Compression
None; 0; BI_RGB
X pixel spacing
0.130000
Y pixel spacing
0.130000
Z pixel spacing
0.130000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
912

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Custom 225/450kV Walk In Micro focus, µ-VIS X-ray Imaging Centre (University of Southampton)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
The Trustees of the Natural History Museum, London
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object NHMUK:PAL:PV R 1089 a was imaged to create this media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
µ-VIS X-ray Imaging Centre (University of Southampton)
Creator
--
Event date
--
Software
--
Description
Voxel sizes: X = 0.13mm Y = 0.13mm Z = 0.13mm
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

Media 000653912: Skull Braincase Image Stack [CTImageSeries] [CT] (this media)