Media 000660772: Right Periotic
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000660772
Media type
Volumetric Image Series
Object element or part
Right periotic
Object taxonomy
Romaleodelphis pollerspoecki
Side
Right
Orientation
--
Short description
TIFF stack from microCT scan of right periotic
Full description
TIFF stack from microCT scan of right periotic of _Romaleodelphis pollerspoecki_
Creator
Rachel Racicot
Date created
September 05, 2024
Date uploaded
September 06, 2024

FILE OBJECT DETAILS Field Definitions

File name
right_periotic.zip
File format(s)
ZIP archive, TIFF
File size
2.94 GB
Image width
1378
Image height
1699
Color space
BlackIsZero
Color depth
8
Compression
PackBits
X pixel spacing
14.800000
Y pixel spacing
14.800000
Z pixel spacing
14.800000
Pixel spacing units
Um
Slice thickness
--
Number of images in set
2,328

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix nanotom m, SNSB X-ray facility (Zoologische Staatssammlung München (Bavarian State Collection of Zoology))

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object snsb-bspg:2018 x:SNSB-BSPG 1992 I 10 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
SNSB X-ray facility (Zoologische Staatssammlung München (Bavarian State Collection of Zoology))
Creator
--
Event date
--
Software
--
Description
microCT scan of the right periotic of _Romaleodelphis pollerspoecki_
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
140 kV
Power
--
Amperage
35 mA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000660772: Right Periotic (this media).

Processing Details Field Definitions

Creator
Rachel Racicot
Event date
September 05, 2024
Software
VGStudio Max 2024.2
Description
Generated a TIFF stack from the original disk image file using export option in VGStudio Max.
Description attachment
None

Media produced by this event on MorphoSource

Media 000660772: Right Periotic (this media)