Media 000677357: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000677357: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000677357
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Colodon occidentalis
Object organization
Side
--
Orientation
--
Short description
HRXCT scan of skull
Full description
University of Texas High-Resolution X-ray CT Facility Archive 0552 and 553
Colbert:
Colodon: Scans of the skull of an immature fossil tapir (Colodon cf. occidentalis, AMNH F.AM 42891; Whitneyan; Shannon Co., South Dakota; northeast of Indian Stronghold on divide between west Big Corral Draw and Cottonwood Cr.; from a lower Protoceras channel, which would be in the upper Oerodont beds or lower Poleslide Member of the Brule Fm. of Jim Bump. Coll. Skinner and Meffer) for Matthew Colbert of the Department of Geological Sciences, The University of Texas at Austin. Scanned by Matthew Colbert on 09 February 2002.
16bit: 1024x1024 16-bit TIFF format. P250D, 420 kV, 4.7 mA, one brass filter, empty container wedge, no offset, integration time 64 ms, slice thickness 0.5 mm, S.O.D. 630 mm, 1400 views, one ray averaged per view, one sample per view, inter-slice spacing 0.4 mm, field of reconstruction 125 mm (maximum field of view 133.03), reconstruction offset 3400, reconstruction scale 1200. Total slices = 556.
Creator
Matthew Colbert
Date created
February 09, 2002
Date uploaded
October 31, 2024
FILE OBJECT DETAILS Field Definitions
File name
16bit.zip
File format(s)
ZIP archive, TIFF
File size
490 MB
Image width
1000
Image height
658
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.100000
Y pixel spacing
0.100000
Z pixel spacing
0.400000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
556
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
American Museum of Natural History
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
oUTCT provided access to these data, funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
amnh:FAM 42891
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
February 09, 2002
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000677357: Skull [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000677357: Skull [CTImageSeries] [CT] (this media)