Media 000042754: Stl Of Skeleton
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000042754: Stl Of Skeleton
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000042754
Media type
Mesh
Object element or part
STL of skeleton
Object represented
Object taxonomy
Parhoplophryne usambaricus
Object organization
Side
--
Orientation
--
Short description
STL of skeleton
Full description
Migrated MorphoSource 1 Media File Title: STL of skeleton Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
March 02, 2018
FILE OBJECT DETAILS Field Definitions
File name
Parhoplophryne_usambaricus_A13818.stl
File format(s)
STL
File size
96.9 MB
Points
1014061
Polygons
2031259
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
12.800, 8.375, 28.231
Centroid coordinates
-0.140, -0.173, 1.299
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714; overt TCN; NSF DBI-1702263
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
MCZ:Herp:A-13818
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Joe Martinez
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1.6
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
5
Projections
800
Voltage
40
Power
0.0068
Amperage
170
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000042516: Skeleton [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Joe Martinez
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000042516: Skeleton [CTImageSeries] [Etc]
was processed
to create
derived
Media 000042754: Stl Of Skeleton [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Joe Martinez
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000042754: Stl Of Skeleton [Mesh] [Etc] (this media)