Media 000452770: Head
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

Media preview currently unavailable. Please check back later.

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000452770
Media type
Volumetric Image Series
Object element or part
Head
Object represented
Object taxonomy
Sciurus carolinensis
Side
NotApplicable
Orientation
--
Short description
Sciurus carolinensis
Full description
DiceCT scan of grey squirrel head
Creator
Jeffery, Nathan
Date created
May 13, 2010
Date uploaded
July 28, 2022

FILE OBJECT DETAILS Field Definitions

File name
Squirrel11_IKI.zip
File format(s)
ZIP archive, TIFF
File size
671 MB
Image width
664
Image height
647
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.080200
Y pixel spacing
0.080200
Z pixel spacing
0.080200
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology 225/320 kV Custom Bay, Henry Moseley X-ray Imaging Facility (University of Manchester)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NERC grant NE/G001952/1
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object hacb:SC11 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Henry Moseley X-ray Imaging Facility (University of Manchester)
Creator
Jeffery, Nathan
Event date
May 13, 2010
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
195
Power
--
Amperage
110
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
664
Detector pixels size X
0.0802
Detector pixels Y
647
Detector pixels size Y
0.0802
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000452770: Head [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000452770: Head [CTImageSeries] [CT] (this media)