Media 000636760: Lower Second Molar
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Media List
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000636760
Media type
Mesh
Object element or part
Lower Second Molar
Object represented
Object taxonomy
Ptilocercus lowii
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Keegan Selig
Date created
June 13, 2024
Date uploaded
June 13, 2024

FILE OBJECT DETAILS Field Definitions

File name
fmnh_76855_p_lowii_lowii.ply
File format(s)
PLY
File size
312 KB
Points
5092
Polygons
9977
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
1.754, 2.573, 1.950
Centroid coordinates
11.131, 4.232, 6.142 (Vertex Mean)
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Field Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Mammals:76855 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UChicago PaleoCT (University of Chicago)
Creator
April Neander
Event date
April 20, 2017
Software
VG StudioMax
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2024
Detector pixels size X
0.2
Detector pixels Y
2024
Detector pixels size Y
0.2
Detector configuration
Area (single or tiled detector)
Source object distance
56.57643750
Source detector distance
939.22555878
Target material
--
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 2 activities to create derived Media 000457239: Dentary, Mandible [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Doug Boyer, April Neander
Event date
August 19, 2022
Software
Avizo; VG Studio Max
Description
reconstruction happened with VG studio Max in 2017; cropping and upload happened with Avizo in 2022
Description attachment
None

Processing Activity 1: Reconstruction

Software
VG Studio Max
Description

Processing Activity 2: Crop

Software
Avizo
Description

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000457239: Dentary, Mandible [CTImageSeries] [CT] was processed to create derived Media 000636760: Lower Second Molar [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Keegan Selig
Event date
--
Software
Avizo; VG Studio Max
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000636760: Lower Second Molar [Mesh] [CT] (this media)