Media 000053026: Hand Ct Scans
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000053026
Media type
Volumetric Image Series
Object element or part
Hand CT scans
Object represented
Object taxonomy
Homo sapiens
Side
--
Orientation
--
Short description
Hand CT scans
Full description
Migrated MorphoSource 1 Media File Title: Hand CT scans Migrated MorphoSource 1 Media Group Title: Raw image data Migrated MorphoSource 1 Media File Description: Bone Plus Reconstruction Migrated MorphoSource 1 Media Group Description: Any 3D surface uploaded for this specimen/element was produced with either the Isosurface or LabelField functions in AMIRA v.5.6 or later, and is best regarded as minimally processed for smoothing and hole filling (unless otherwise noted). If raw image data (i.e., slices) for this specimen/element have been uploaded, they may appear as a single 3D Tiff format file produced in AMIRA v.5.6 or later. This file can be opened in most versions of AMIRA or AVIZO without needing additional input for scale (i.e., the voxel resolution is recognized). This file can also be opened in ImageJ but will require the user to scale the images with provided information on voxel dimensions prior to working with them.
Creator
--
Date created
--
Date uploaded
July 02, 2018

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, DICOM
File size
200 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.187500
Y pixel spacing
0.187500
Z pixel spacing
0.187000
Pixel spacing units
Mm
Slice thickness
0.625000
Number of images in set
1,175

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT, Stony Brook University Medical Center (Stony Brook University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Biren Patel
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
National Science Foundation [BCS 1317047 (to Biren Patel), BCS 1539741 (to Caley Orr)], the L.S.B. Leakey Foundation (to Biren Patel), the Wenner-Gren Foundation (to Caley Orr), and the University of Southern California (to Biren Patel).
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Biren Patel and Caley Orr provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object sbu:AS-Hand42 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Stony Brook University Medical Center (Stony Brook University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000053026: Hand Ct Scans [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000053026: Hand Ct Scans [CTImageSeries] [Etc] (this media)