Media 000055276: Partial Left Dentary With P3 M1 Trigonid
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000055276: Partial Left Dentary With P3 M1 Trigonid
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000055276
Media type
Volumetric Image Series
Object element or part
Partial left dentary with p3-m1 trigonid
Object represented
Object taxonomy
Bownomomys americanus
Object organization
Side
Left
Orientation
--
Short description
Raw scan of dentary
Full description
Migrated MorphoSource 1 Media File Title: Raw scan of dentary Migrated MorphoSource 1 Media Group Title: Scan of UW 7170 measured by Morse et al. (2018)
Creator
--
Date created
--
Date uploaded
July 22, 2018
FILE OBJECT DETAILS Field Definitions
File name
UW-7170_Cropped.zip
File format(s)
ZIP archive, TIFF
File size
590 MB
Image width
958
Image height
1180
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.004578
Y pixel spacing
0.004578
Z pixel spacing
0.004578
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
816
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
P.E. Morse
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DGE-1315138 to P.E. Morse
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Paul E. Morse provided access to these datawhich first appeared in Morse et al. (2018). , the collection of which was funded by. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
uw:7170
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Paul E. Morse
Event date
--
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
2300
Voltage
70
Power
--
Amperage
70
Surrounding material
styrofoam
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000055276: Partial Left Dentary With P3 M1 Trigonid [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Paul E. Morse
Event date
--
Software
--
Description
--
Description attachment
None