Media 000055300: Mandible
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

Media preview currently unavailable. Please check back later.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000055300
Media type
Volumetric Image Series
Object element or part
Mandible
Object represented
Object taxonomy
Heterocephalus glaber
Side
--
Orientation
--
Short description
Heterocephalus glaber
Full description
Migrated MorphoSource 1 Media File Title: Heterocephalus glaber Migrated MorphoSource 1 Media Group Title: MicroCT stack
Creator
--
Date created
--
Date uploaded
July 23, 2018

FILE OBJECT DETAILS Field Definitions

File name
Heterocephalus-572-mandible-stack.zip
File format(s)
ZIP archive, TIFF
File size
535 MB
Image width
980
Image height
1089
Color space
BlackIsZero
Color depth
8
Compression
--
X pixel spacing
0.018285
Y pixel spacing
0.018285
Z pixel spacing
0.018285
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX 160, Department of Engineering (Medical and Biomedical) (University of Hull)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
MNHN-Paris
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
Encouraged But Not Required
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object mnhn:zm:MO-1911-572 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Department of Engineering (Medical and Biomedical) (University of Hull)
Creator
Sue Taft
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000055300: Mandible [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Sue Taft
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000055300: Mandible [CTImageSeries] [Etc] (this media)