Media 000056192: Cranium
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000056192: Cranium
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000056192
Media type
Volumetric Image Series
Object element or part
cranium
Object represented
Object taxonomy
Shoshonius cooperi
Object organization
Side
NotApplicable
Orientation
--
Short description
zipped dicom stack
Full description
Migrated MorphoSource 1 Media File Title: zipped dicom stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives Migrated MorphoSource 1 Media File Description: correct chirality
Creator
--
Date created
--
Date uploaded
August 07, 2018
FILE OBJECT DETAILS Field Definitions
File name
CM_40693_shoshonius_cranium.zip
File format(s)
ZIP archive, DICOM
File size
5.71 GB
Image width
1232
Image height
1600
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.012753
Y pixel spacing
0.012753
Z pixel spacing
0.012753
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,338
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Carnegie Museum of Natural History, Section of Vertebrate Paleontoloogy
Copyright statement
--
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1440742 (to DMB & GFG), NSF BSC 1440558 (to JIB), and NSF BCS 1552848 (to DMB)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these data , the collection of which was funded by NSF BCS 1440742 (to DMB & GFG), NSF BSC 1440558 (to JIB), and NSF BCS 1552848 (to DMB). The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
cm:vertpaleo:060493
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer, Mackenzie Shepard
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
0.500
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
2000
Voltage
145
Power
--
Amperage
67
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000056192: Cranium [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Doug Boyer, Mackenzie Shepard
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000056192: Cranium [CTImageSeries] [Etc] (this media)