Media 000058005: Full Body
Restricted Download
Type
Image
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000058005: Full Body
Restricted Download
Type
Image
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000058005
Media type
Image
Object element or part
full body
Object represented
Object taxonomy
Pan troglodytes
Object organization
Side
NotApplicable
Orientation
--
Short description
preview of dicom stack
Full description
Migrated MorphoSource 1 Media File Title: preview of dicom stack Migrated MorphoSource 1 Media Group Title: medical CT volume and derivatives Migrated MorphoSource 1 Media File Description: correct chirality Migrated MorphoSource 1 Media Group Description: correct chirality
Creator
--
Date created
--
Date uploaded
September 17, 2018
FILE OBJECT DETAILS Field Definitions
File name
snapshot.jpg
File format(s)
JPEG
File size
443 KB
Image width
2769
Image height
2679
Color space
YCbCr
Color depth
8
Compression
JPEG
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric Discovery NM/CT 570c, Yale Translational Research Imaging Center (Y-TRIC) (Yale University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Yale University
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
BCS-1552848); NSF (DBI-1701769; DBI-1701714
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Greg Watkins-Colwell provided access to these data , the collection of which was funded by NSF (DBI-1701769. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
YPM:VZ:YPM MAM 015939
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Yale Translational Research Imaging Center (Y-TRIC) (Yale University)
Creator
Doug Boyer, Attila Feher, and Nabil Boutagy
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
nr
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
nr
Projections
nr
Voltage
120
Power
0.0
Amperage
nr
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000058004: Full Body [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Doug Boyer, Attila Feher, and Nabil Boutagy
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000058004: Full Body [CTImageSeries] [Etc]
was processed
to create
derived
Media 000058005: Full Body [Image] [Etc] (this media).
Processing Details Field Definitions
Creator
Doug Boyer, Attila Feher, and Nabil Boutagy
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000058005: Full Body [Image] [Etc] (this media)