Media 000071608: Toothrow
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000071608: Toothrow
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000071608
Media type
Volumetric Image Series
Object element or part
toothrow
Object represented
Object taxonomy
Pronothodectes jepi
Object organization
Side
--
Orientation
--
Short description
tiff stack
Full description
Migrated MorphoSource 1 Media File Title: tiff stack Migrated MorphoSource 1 Media Group Title: toothrow
Creator
--
Date created
--
Date uploaded
March 10, 2019
FILE OBJECT DETAILS Field Definitions
File name
14783.zip
File format(s)
ZIP archive, TIFF
File size
168 MB
Image width
402
Image height
314
Color space
BlackIsZero
Color depth
16
Compression
LZW
X pixel spacing
0.023845
Y pixel spacing
0.023845
Z pixel spacing
0.023845
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
767
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
SMiF
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
YPM:VP:YPM VPPU 014783
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Ethan Fulwood
Event date
June 03, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
2000
Voltage
180
Power
--
Amperage
73
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000071608: Toothrow [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Ethan Fulwood
Event date
June 03, 2021
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000071608: Toothrow [CTImageSeries] [CT] (this media)