Media 000077558: Maxilla With M1, M2
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000077558
Media type
Volumetric Image Series
Object element or part
maxilla with m1, m2
Object represented
Object taxonomy
Plesiadapis fodinatus
Side
Right
Orientation
--
Short description
Zipped Tiff Stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped Tiff Stack Migrated MorphoSource 1 Media Group Title: microCT Volume and Derivatives Migrated MorphoSource 1 Media Group Description: correct chirality
Creator
--
Date created
--
Date uploaded
May 16, 2019

FILE OBJECT DETAILS Field Definitions

File name
YPM020621_R-max.zip
File format(s)
ZIP archive, TIFF
File size
345 MB
Image width
567
Image height
540
Color space
BlackIsZero
Color depth
16
Compression
LZW
X pixel spacing
0.019665
Y pixel spacing
0.019665
Z pixel spacing
0.019665
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
663

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Yale Peabody Museum
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object YPM:VP:YPM VPPU 020621 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Keegan Selig, Doug Boyer
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.267
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
4
Projections
2200
Voltage
190
Power
--
Amperage
89
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000077558: Maxilla With M1, M2 [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Keegan Selig, Doug Boyer
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000077558: Maxilla With M1, M2 [CTImageSeries] [Etc] (this media)