Media 000084089: Partial Humerus
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000084089
Media type
Volumetric Image Series
Object element or part
partial humerus
Object represented
Object taxonomy
Rahonavis ostromi
Side
Left
Orientation
--
Short description
FMNH PA 746 partial left humerus
Full description
Migrated MorphoSource 1 Media File Title: FMNH PA 746 partial left humerus Migrated MorphoSource 1 Media Group Title: micro-CT volume data and polygon derivative
Creator
--
Date created
--
Date uploaded
August 01, 2019

FILE OBJECT DETAILS Field Definitions

File name
UA_9604-DICOM.zip
File format(s)
ZIP archive, DICOM
File size
90 MB
Image width
366
Image height
226
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.049300
Y pixel spacing
0.049300
Z pixel spacing
0.049300
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
795

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric eXplore CT 120 in vivo, Ohio University MicroCT Facility (Ohio University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Patrick O'Connor
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF EAR-1525915
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Patrick O'Connor and colleagues provided access to these datapublished in conjunction with Forster et al. 2020. with funding from the National Science Foundation. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:PA:746 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Ohio University MicroCT Facility (Ohio University)
Creator
Ryan Ridgley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.02
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
4
Projections
--
Voltage
120
Power
0.0038399999999999997
Amperage
32
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000084089: Partial Humerus [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Ryan Ridgley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000084089: Partial Humerus [CTImageSeries] [Etc] (this media)