Media 000494624: Angular
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000494624: Angular
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
Media preview currently unavailable. Please check back later.
In Collections
Team
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000494624
Media type
Mesh
Object element or part
angular
Object represented
Object taxonomy
Majungasaurus crenatissimus
Object organization
Side
Right
Orientation
--
Short description
right angular
Full description
--
Creator
Groenke, Joseph
Date created
February 03, 2020
Date uploaded
January 26, 2023
FILE OBJECT DETAILS Field Definitions
File name
FMNH_PR_2278_r_angular.zip
File format(s)
ZIP archive, DICOM
File size
53.7 MB
Points
--
Polygons
--
Map type
Normal
UV coordinates
--
Vertex color
--
Bounding box dimensions
--
Centroid coordinates
--
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT, Stony Brook University Medical Center (Stony Brook University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Field Museum of Natural History
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF EAR_1525915; Ohio University Heritage College of Osteopathic Medicine; NSF EAR_1123642; NSF DBI_2242717; NSF EAR_9418816
Publisher
O'Connor, Patrick; Mahajanga Basin Project
Cite as
Patrick M. O'Connor and colleagues provided access to these data originally published in SVP Memoir 8 (2007, Vol. 27, Suppl. 2) with data collection and processing funded by the US NSF EAR_9418816, NSF EAR_1123642, NSF EAR_1525915, NSF DBI_2242717 and Ohio University Heritage College of Osteopathic Medicine. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
FMNH:PR:2278
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Stony Brook University Medical Center (Stony Brook University)
Creator
Groenke, Joseph
Event date
May 14, 2012
Software
GE gmp_vct.26
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1825
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
140
Power
--
Amperage
250
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
512
Detector pixels size X
0.1875
Detector pixels Y
140
Detector pixels size Y
0.1875
Detector configuration
Slot (scanned slot, slit, or spot)
Source object distance
541
Source detector distance
949.075012
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Spiral
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000494621: Angular [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Groenke, Joseph
Event date
November 01, 2022
Software
Avizo
Description
cropping and output as dicoms to replace field number(s) with museum accession number
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000494621: Angular [CTImageSeries] [CT]
was processed
to create
derived
Media 000494624: Angular [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Groenke, Joseph
Event date
February 03, 2020
Software
Avizo
Description
export ply format from isosurface rendering
Description attachment
None
Media produced by this event on MorphoSource
Media 000494624: Angular [Mesh] [CT] (this media)