Media 000495625: Postdentary
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000495625
Media type
Volumetric Image Series
Object element or part
postdentary
Object represented
Object taxonomy
Majungasaurus crenatissimus
Side
Left
Orientation
--
Short description
left postdentary
Full description
--
Creator
Groenke, Joseph
Date created
October 27, 2022
Date uploaded
February 03, 2023

FILE OBJECT DETAILS Field Definitions

File name
FMNH_PR_2278_l_postdentary.zip
File format(s)
ZIP archive, DICOM
File size
320 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.265625
Y pixel spacing
0.265625
Z pixel spacing
0.200000
Pixel spacing units
Mm
Slice thickness
0.625000
Number of images in set
1,604

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT, Stony Brook University Medical Center (Stony Brook University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Field Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF EAR_1525915; Ohio University Heritage College of Osteopathic Medicine; NSF EAR_1123642; NSF DBI_2242717; NSF EAR_9418816
Publisher
O'Connor, Patrick; Mahajanga Basin Project
Cite as
Patrick M. O'Connor and colleagues provided access to these data originally published in SVP Memoir 8 (2007, Vol. 27, Suppl. 2) with data collection and processing funded by the US NSF EAR_9418816, NSF EAR_1123642, NSF EAR_1525915, NSF DBI_2242717 and Ohio University Heritage College of Osteopathic Medicine. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:PR:2278 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Stony Brook University Medical Center (Stony Brook University)
Creator
Groenke, Joseph
Event date
May 15, 2012
Software
GE gmp_vct.26
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1825
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
140
Power
--
Amperage
250
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
512
Detector pixels size X
0.265625
Detector pixels Y
512
Detector pixels size Y
0.265625
Detector configuration
Slot (scanned slot, slit, or spot)
Source object distance
541
Source detector distance
949.075012
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Spiral

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000495625: Postdentary [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Groenke, Joseph
Event date
October 27, 2022
Software
Avizo
Description
cropping and output as dicoms to replace field number(s) with museum accession number
Description attachment
None

Media produced by this event on MorphoSource

Media 000495625: Postdentary [CTImageSeries] [CT] (this media)