Media 000086223: Left Ear Centred
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000086223
Media type
Volumetric Image Series
Object element or part
Left ear centred
Object represented
Object taxonomy
Nycticebus coucang
Side
Midline
Orientation
--
Short description
Basicranium
Full description
Migrated MorphoSource 1 Media File Title: Basicranium Migrated MorphoSource 1 Media Group Title: microCT volume
Creator
--
Date created
--
Date uploaded
September 11, 2019

FILE OBJECT DETAILS Field Definitions

File name
Nycticebus_Nycticebus-coucang_CG1882-2933_CG1882-2933G.zip
File format(s)
ZIP archive, TIFF
File size
1.47 GB
Image width
1304
Image height
1304
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.029400
Y pixel spacing
0.029400
Z pixel spacing
0.029400
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
937

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1174, MorphOptics - Biogéosciences (L'université de Bourgogne)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
MNHN-Paris
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
Encouraged But Not Required
Funding attribution
Conseil Régional de Bourgogne FABER, Grant/Award Number: CRB_9201AAO047S01518; Synthesys, Grant/Award Number: GB-TAF 4120
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Sébastien Couette provided access to these dataoriginally appearing in Bernardi M, Couette S, Chateau Smith C, Montuire S. Middle ear pneumatization in nonhuman primates: A comparative analysis. Am J Phys Anthropol. 2019. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object mnhn:zm:CG 1882-2933 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
MorphOptics - Biogéosciences (L'université de Bourgogne)
Creator
Margot Bernardi, Sébastien Couette, Emilie Steimetz
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
4.4
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
380
Voltage
50
Power
0.04
Amperage
800
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000086223: Left Ear Centred [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Margot Bernardi, Sébastien Couette, Emilie Steimetz
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000086223: Left Ear Centred [CTImageSeries] [Etc] (this media)