Media 000100917: Humerus
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000100917: Humerus
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Team
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000100917
Media type
Mesh
Object element or part
Humerus
Object represented
Object taxonomy
Arenophryne rotunda
Object organization
Side
Right
Orientation
--
Short description
CT scan of AMNH106749 Arenophryne rotunda
Full description
Migrated MorphoSource 1 Media File Title: CT scan of AMNH106749 Arenophryne rotunda Migrated MorphoSource 1 Media Group Title: CT scan of AMNH106749 Arenophryne rotunda
Creator
--
Date created
--
Date uploaded
February 13, 2020
FILE OBJECT DETAILS Field Definitions
File name
Arenophryne_rotunda_AMNH106749_right_humerus.stl
File format(s)
STL
File size
1.19 MB
Points
12479
Polygons
24975
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
2.340, 3.474, 1.710
Centroid coordinates
1.426, -0.251, -7.237
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
AMNH:Herpetology:A-106749
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Ed Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
2000
Voltage
70
Power
0.014
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000100591: Whole Body [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Ed Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000100591: Whole Body [CTImageSeries] [Etc]
was processed
to create
derived
Media 000100917: Humerus [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Ed Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000100917: Humerus [Mesh] [Etc] (this media)