Media 000101378: Cranium
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000101378: Cranium
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000101378
Media type
Volumetric Image Series
Object element or part
Cranium
Object represented
Object taxonomy
Irritator challengeri
Object organization
Side
--
Orientation
--
Short description
DICOM stack of cranium
Full description
Migrated MorphoSource 1 Media File Title: DICOM stack of cranium Migrated MorphoSource 1 Media Group Title: DICOM stack of crnaium Migrated MorphoSource 1 Media Group Description: We would ask you to kindly contact Marco Schade (marco.schade@stud.uni-greifswald.de) if you want to use the CT data for descriptive purposes, as we are using the scans to prepare a redescription of Irritator.
Creator
--
Date created
--
Date uploaded
February 21, 2020
FILE OBJECT DETAILS Field Definitions
File name
Irritator_challengeri_SMNS58022_Somatom_DICOM.zip
File format(s)
ZIP archive, DICOM
File size
640 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.703125
Y pixel spacing
0.703125
Z pixel spacing
0.300000
Pixel spacing units
Mm
Slice thickness
0.5000000
Number of images in set
2,476
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Somatom Force, Deutsches Herzzentrum Munich (Deutsches Herzzentrum Munich)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
SMNS Stuttgart
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Marco Schade provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
smns:58022
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Deutsches Herzzentrum Munich (Deutsches Herzzentrum Munich)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
365
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
120
Power
--
Amperage
1365000
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000101378: Cranium [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000101378: Cranium [CTImageSeries] [Etc] (this media)