Media 000166129: Skull And Hyoid
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000166129: Skull And Hyoid
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000166129
Media type
Mesh
Object element or part
skull and hyoid
Object represented
Object taxonomy
Yaksha perettii
Object organization
Side
--
Orientation
--
Short description
Shape file (obj)
Full description
Migrated MorphoSource 1 Media File Title: Shape file (obj) Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives of GRS:Amber:060829
Creator
--
Date created
--
Date uploaded
October 29, 2020
FILE OBJECT DETAILS Field Definitions
File name
Yaksha-perettii-skull.obj
File format(s)
OBJ
File size
295 MB
Points
1500654
Polygons
3004334
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
15.597, 7.977, 5.780
Centroid coordinates
1.408, 0.296, 0.387
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
Peretti Museum Foundation
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
grs:amber:060829
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
February 14, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
3000
Voltage
130
Power
0.0169
Amperage
130
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000104768: Head [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Matthew Colbert
Event date
February 14, 2021
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000104768: Head [CTImageSeries] [CT]
was processed
to create
derived
Media 000166129: Skull And Hyoid [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Matthew Colbert
Event date
February 14, 2021
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000166129: Skull And Hyoid [Mesh] [CT] (this media)