Media 000166157: Skull, Hyoid And Soft Tissue
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000166157
Media type
Mesh
Object element or part
skull, hyoid and soft tissue
Object represented
Object taxonomy
Yaksha perettii
Object organization
Side
--
Orientation
--
Short description
Shape file (obj)
Full description
Migrated MorphoSource 1 Media File Title: Shape file (obj) Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives of GRS:Amber:060829
Creator
--
Date created
--
Date uploaded
October 30, 2020

FILE OBJECT DETAILS Field Definitions

File name
6547_ms_media_files_media_166157_original-000166157.ply
File format(s)
PLY
File size
94.8 MB
Points
2162199
Polygons
4329277
Map type
--
UV coordinates
False
Vertex color
True
Bounding box dimensions
15.597, 8.125, 5.849
Centroid coordinates
2.008, 0.377, 0.193
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
Peretti Museum Foundation
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object grs:amber:060829 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
February 14, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
3000
Voltage
130
Power
0.0169
Amperage
130
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000104768: Head [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
February 14, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000104768: Head [CTImageSeries] [CT] was processed to create derived Media 000166157: Skull, Hyoid And Soft Tissue [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
February 14, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000166157: Skull, Hyoid And Soft Tissue [Mesh] [CT] (this media)