Media 000114137: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Media 000114137: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000114137
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Pecari tajacu bangsi
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 2814\\r\\n\\r\\nVanValkenburgh:\\r\\npecari: Scans of the skull of Pecari tajacu bangsi (USNM 338365) for Blaire Van Valkenburgh of the University of California Los Angeles Department of Organismic Biology. Scanned by Matthew Colbert 20 September 2012.\\r\\n\\r\\n16bit: 1024x1024 16-bit TIFF images. P250D, 450 kV, 3 mA, large spot, 1 brass filter, air wedge, no offset, 20 ms integration time, slice thickness = 0.5 mm, S.O.D. 576 mm, 1320 views, 1 ray averaged per view, 1 sample per view, inter-slice spacing = 0.45 mm, field of reconstruction 223 mm (maximum field of view 230.3758 mm. Field of view reported on scan form corresponds to a corrected value after applying a correction of 1.01319%. Field of view used in ACTIS equals 220.0969 mm. Reported maximum field of view reflects uncorrected value) reconstruction offset 5000, reconstruction scale 7000. Ring-removal processing done by Julia Holland based on correction of raw sinogram data using IDL routine “RK_SinoRingProcSimul” with parameter “sectors=100.” Total slices = 378.\\r\\n
Creator
--
Date created
--
Date uploaded
April 05, 2020
FILE OBJECT DETAILS Field Definitions
File name
16bit.zip
File format(s)
ZIP archive, TIFF
File size
302 MB
Image width
537
Image height
992
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.218000
Y pixel spacing
0.218000
Z pixel spacing
0.450000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
378
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
IOS-1119768, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Blaire Van Valkenburgh and Tim Rowe provided access to these data , with data collection funded by NSF IOS-1119768 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
USNM:MAMM:USNM 338365
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
1320
Voltage
450
Power
--
Amperage
3000
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000114137: Skull [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000114137: Skull [CTImageSeries] [Etc] (this media)