Media 000114916: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000114916: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000114916
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Crocodylus cataphractus
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 1275\\r\\n\\r\\nBrochu:\\r\\nCataphractus: Scans of the head of Crocodylus cataphractus (TMM M-3529) for Chris Brochu of The University of Iowa. Specimen scanned by Matthew Colbert 16 July 2005.\\r\\n\\r\\n16bit: 1024x1024 16-bit TIFF images. P250D, 420 kV, 1.8 mA, no filter, 130% offset, empty container wedge, integration time = 32 ms, slice thickness = 0.5 mm, S.O.D. 643 mm, 1000 views, 1 sample per view, inter-slice spacing = 0.46 mm, field of reconstruction 169 mm (maximum field of view 169.3914 mm, reconstruction offset 8000, scanner scale 6500, reconstruction scale 2100. Reconstructed with an angle of -8 degrees and beam hardening coefficients 0, 0.8, 0.05. Slices 1-3 deleted, as they were blank. Total final slices = 818.\\r\\n\\n\\nRelated URL: http://digimorph.org/specimens/Crocodylus_cataphractus/ Migrated MorphoSource 1 Media Group Description: Related URL: http://digimorph.org/specimens/Crocodylus_cataphractus/
Creator
--
Date created
--
Date uploaded
April 26, 2020
FILE OBJECT DETAILS Field Definitions
File name
16bit.zip
File format(s)
ZIP archive, TIFF
File size
780 MB
Image width
978
Image height
684
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.165000
Y pixel spacing
0.165000
Z pixel spacing
0.460000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
818
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Memorial Museum
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
DEB-0444133, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Chris Brochu provided access to these data , with data collection funded by NSF DEB-0444133 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
tmm:m:3529
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
1000
Voltage
420
Power
--
Amperage
1800
Surrounding material
empty container
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000114916: Skull [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000114916: Skull [CTImageSeries] [Etc] (this media)