Media 000115747: Head
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
· Public
Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000115747
Media type
Volumetric Image Series
Object element or part
head
Object represented
Object taxonomy
Liasis papuana
Object organization
Side
--
Orientation
--
Short description
HRXCT scan - head
Full description
University of Texas High-Resolution X-ray CT Facility Archive Gheur: MCZ2190-AMNH73992_: Scan of two snake heads Python molurus bivattatus (MCZ R-2190; Asia: Indonesia: Central Java Province: Java Java) at bottom of field of view; and Apodora papuana (AMNH 73992; Papua New Guinea; Milne Bay; Biniguni Village, Gwariu R; coll. 2 Aug. 1953 by G.M. Tate) at top of field of view; for Damien Esquerre Gheur and Scott Keogh of The Australian National University. Specimens scanned by Matthew Colbert on 22 November 2016. 16bitTIFF: Scan parameters: NSI scanner. Fein Focus High Power source, 170 kV, 0.19 mA, aluminum filter, Perkin Elmer detector, 0.25 pF gain, 1 fps, 1x1 binning, no flip, source to object 340.0 mm, source to detector 1316.827 mm, continuous CT scan, no frames averaged, 0 skip frames, 3600 projections, 6 gain calibrations, 15 mm calibration phantom, data range [-0.5, 10.0] (grayscales adjusted from NSI defaults), beam-hardening correction = 0.1. Slices flipped and reordered in ImageJ. Voxel size = 56.3 μm. Total slices = 1726.
Creator
--
Date created
November 22, 2016
Date uploaded
May 06, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
3.09 GB
Image width
1110
Image height
1032
Color space
BlackIsZero
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.056300
Y pixel spacing
0.056300
Z pixel spacing
0.056300
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,726

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
American Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
Australian Research Council Discovery grant (DP150102403), NSF DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Scott Keogh and Damien Esquerre Gheur provided access to these data , with data collection funded by DP150102403 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object AMNH:Herpetology:R-73992 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
3600
Voltage
170
Power
--
Amperage
190
Surrounding material
0.25 pF gain
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000115747: Head [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000115747: Head [CTImageSeries] [CT] (this media)