Media 000169812: Lunate
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000169812: Lunate
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000169812
Media type
Mesh
Object element or part
Lunate
Object represented
Object taxonomy
Adalatherium hui
Object organization
Side
Left
Orientation
--
Short description
Adalatherium_Lunate
Full description
Migrated MorphoSource 1 Media File Title: Adalatherium_Lunate Migrated MorphoSource 1 Media Group Title: Lunate
Creator
Simone Hoffmann
Date created
--
Date uploaded
December 16, 2020
FILE OBJECT DETAILS Field Definitions
File name
Lunate_L.ply
File format(s)
PLY
File size
4.51 MB
Points
66972
Polygons
133929
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
5.305, 7.937, 6.815
Centroid coordinates
5.485, -12.999, 9.885
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric eXplore Locus in vivo, Ohio University MicroCT Facility (Ohio University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Simone Hoffmann; Patrick O'Connor
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF EAR_1123642; NSF EAR_9418816; NSF DBI_2242717; Ohio University Heritage College of Osteopathic Medicine; NSF EAR_1525915
Publisher
Mahajanga Basin Project; Patrick O’Connor; David Krause
Cite as
David Krause and Simone Hoffmann provided access to these data. The specimen was published in Krause et al., 2020, with funding from the National Science Foundation. Additional funding from NSF Division of Biological Infrastructure and Ohio University College of Osteopathic Medicine was used in the creation, organization, and/or dissemination of digital representations of the specimen. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ua:9030
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Ohio University MicroCT Facility (Ohio University)
Creator
--
Event date
--
Software
--
Description
Voxel Size = 0.044782 mm
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
80
Power
--
Amperage
498
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000169812: Lunate [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000169812: Lunate [Mesh] [CT] (this media)