Media 000170025: Lower Right Quadrant, Postcanine 2
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000170025
Media type
Mesh
Object element or part
lower right quadrant, postcanine 2
Object represented
Object taxonomy
Adalatherium hui
Side
Right
Orientation
--
Short description
lower right quadrant, postcanine 2
Full description
Migrated MorphoSource 1 Media File Title: lower right quadrant, postcanine 2 Migrated MorphoSource 1 Media Group Title: Reconstructed teeth, lower right quadrant
Creator
Joseph Groenke
Date created
--
Date uploaded
December 18, 2020

FILE OBJECT DETAILS Field Definitions

File name
lo_R_pc2.ply
File format(s)
PLY
File size
7.68 MB
Points
113804
Polygons
227622
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
10.449, 6.885, 7.678
Centroid coordinates
13.014, 23.248, 50.243
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Avonix Imaging (Avonix Imaging)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Patrick O'Connor; David Krause
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF EAR_1123642; NSF EAR_9418816; NSF DBI_2242717; Ohio University Heritage College of Osteopathic Medicine; NSF EAR_1525915
Publisher
Mahajanga Basin Project; Patrick O’Connor; David Krause
Cite as
David Krause and Simone Hoffmann provided access to these data. The specimen was published in Krause et al., 2020, with funding from the National Science Foundation. Additional funding from NSF Division of Biological Infrastructure and Ohio University College of Osteopathic Medicine was used in the creation, organization, and/or dissemination of digital representations of the specimen. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ua:9030 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Avonix Imaging (Avonix Imaging)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
160
Power
--
Amperage
58
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000170025: Lower Right Quadrant, Postcanine 2 [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000170025: Lower Right Quadrant, Postcanine 2 [Mesh] [CT] (this media)