Media 000159510: Ct Scan Slice
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000159510: Ct Scan Slice
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
No collections found.
TAGS
GENERAL DETAILS Field Definitions
Media ID
000159510
Media type
Volumetric Image Series
Object element or part
Ct scan slice
Object represented
Object taxonomy
Synapturanus sp. Guyana
Object organization
Side
--
Orientation
--
Short description
CT scan slice SMNS12078
Full description
Migrated MorphoSource 1 Media File Title: CT scan slice SMNS12078 Migrated MorphoSource 1 Media Group Title: Synapturanus sp. Guyana collected at Mabura hill forest reserve (Guyana)
Creator
--
Date created
--
Date uploaded
September 18, 2020
FILE OBJECT DETAILS Field Definitions
File name
SMNS12078_Slices.zip
File format(s)
ZIP archive, TIFF
File size
10.2 GB
Image width
1680
Image height
1467
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.011900
Y pixel spacing
0.011900
Z pixel spacing
0.011900
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
3,410
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker Skyscan 1076, Montpellier Resources Imagerie: Institut des Sciences de l’Evolution de Montpellier (MRI-ISEM) (Université de Montpellier)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
smns:12078
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Montpellier Resources Imagerie: Institut des Sciences de l’Evolution de Montpellier (MRI-ISEM) (Université de Montpellier)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
50
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000159510: Ct Scan Slice [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000159510: Ct Scan Slice [CTImageSeries] [Etc] (this media)