Media 000162260: Whole Jaw
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000162260
Media type
Volumetric Image Series
Object element or part
whole jaw
Object represented
Object taxonomy
Powichthys thorsteinssoni
Side
Left
Orientation
--
Short description
Xradia scan whole jaw
Full description
Migrated MorphoSource 1 Media File Title: Xradia scan whole jaw Migrated MorphoSource 1 Media Group Title: Xradia scan whole jaw
Creator
--
Date created
--
Date uploaded
September 30, 2020

FILE OBJECT DETAILS Field Definitions

File name
Ex-Go-100-285-stitch-A-recon.zip
File format(s)
ZIP archive, TIFF
File size
971 MB
Image width
999
Image height
1024
Color space
RGB
Color depth
8/8/8
Compression
Uncompressed
X pixel spacing
0.028146
Y pixel spacing
0.028146
Z pixel spacing
0.028146
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,892

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-510, Naturalis Laboratories (Naturalis Biodiversity Center)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object gzg:v:29285 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Naturalis Laboratories (Naturalis Biodiversity Center)
Creator
Bertie-Joan van Heuven
Event date
April 14, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
18
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
1401
Voltage
50
Power
0.004
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000162260: Whole Jaw [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Bertie-Joan van Heuven
Event date
April 14, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000162260: Whole Jaw [CTImageSeries] [CT] (this media)