Media 000166689: Whole Preserved Fetus
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000166689
Media type
Volumetric Image Series
Object element or part
whole preserved fetus
Object represented
Object taxonomy
Megaptera novaeangliae
Side
--
Orientation
--
Short description
zip 16bit TIFF stack
Full description
Migrated MorphoSource 1 Media File Title: zip 16bit TIFF stack Migrated MorphoSource 1 Media Group Title: CT scan images before iodine staining
Creator
--
Date created
--
Date uploaded
November 10, 2020

FILE OBJECT DETAILS Field Definitions

File name
oldhumpbackTIFF.zip
File format(s)
ZIP archive, TIFF
File size
1.73 GB
Image width
1988
Image height
1988
Color space
BlackIsZero
Color depth
8
Compression
--
X pixel spacing
0.145900
Y pixel spacing
0.145900
Z pixel spacing
0.145900
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
3,474

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Agnese Lanzetti and Eric G. Ekdale provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object sdnhm:25552 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
February 11, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
150
Power
--
Amperage
110
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000166689: Whole Preserved Fetus [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
February 11, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000166689: Whole Preserved Fetus [CTImageSeries] [CT] (this media)