Media 000166919: Skeletonized Axial Column
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000166919
Media type
Volumetric Image Series
Object element or part
skeletonized axial column
Object taxonomy
Intellagama lesueurii
Side
--
Orientation
--
Short description
zipped tiff stack
Full description
microCT volume and derivatives
Creator
Baumgart, Stephanie
Date created
--
Date uploaded
November 17, 2020

FILE OBJECT DETAILS Field Definitions

File name
FMNH_H_22389_Physignathus_ImageStack.zip
File format(s)
ZIP archive, TIFF
File size
396 MB
Image width
692
Image height
677
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.057426
Y pixel spacing
0.057426
Z pixel spacing
0.057426
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
3,298

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Sereno lab
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
Generous donations to Paul Sereno by Bob and Ellen Vladem and SC Johnson
Publisher
--
Cite as
The Sereno lab and the Field Museum of Natural History provided access to these data, the collection of which was funded by gifts and donations to Paul Sereno. The data was first used in Sereno et al. 2022. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Amphibians and Reptiles:22389 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UChicago PaleoCT (University of Chicago)
Creator
Stephanie Baumgart
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.250094
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1100
Voltage
140
Power
0.033600000000000005
Amperage
240
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000166919: Skeletonized Axial Column [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Stephanie Baumgart
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000166919: Skeletonized Axial Column [CTImageSeries] [CT] (this media)