Media 000166919: Skeletonized Axial Column
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000166919: Skeletonized Axial Column
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000166919
Media type
Volumetric Image Series
Object element or part
skeletonized axial column
Object represented
Object taxonomy
Intellagama lesueurii
Object organization
Side
--
Orientation
--
Short description
zipped tiff stack
Full description
microCT volume and derivatives
Creator
Baumgart, Stephanie
Date created
--
Date uploaded
November 17, 2020
FILE OBJECT DETAILS Field Definitions
File name
FMNH_H_22389_Physignathus_ImageStack.zip
File format(s)
ZIP archive, TIFF
File size
396 MB
Image width
692
Image height
677
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.057426
Y pixel spacing
0.057426
Z pixel spacing
0.057426
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
3,298
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Sereno lab
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
Generous donations to Paul Sereno by Bob and Ellen Vladem and SC Johnson
Publisher
--
Cite as
The Sereno lab and the Field Museum of Natural History provided access to these data, the collection of which was funded by gifts and donations to Paul Sereno. The data was first used in Sereno et al. 2022. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
FMNH:Amphibians and Reptiles:22389
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UChicago PaleoCT (University of Chicago)
Creator
Stephanie Baumgart
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.250094
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1100
Voltage
140
Power
0.033600000000000005
Amperage
240
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000166919: Skeletonized Axial Column [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Stephanie Baumgart
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000166919: Skeletonized Axial Column [CTImageSeries] [CT] (this media)